Features
• V2 to V5 can be configured to be either +5V, +3.3V, +24V, -5V, or -12V O/P
• When V2, V3, V4 are used in parallel (+5V or +3.3V O/P), the O/P is derated to 90% of max. rated current
• Remote ON / OFF: High state / PS OFF, Low state / PS ON
• PG Delay: 100-500 msec. ; PF Delay: > 1 msec.
• Hold - Up Time: 12 msec. (minimum) @ 80% load
• Rise Time: 20 msec. (maximum) @ full load
• Power-on time: 200 msec. (maximum) @ full load
• Support OPP, OCP, OVP and SCP
Electrical Specification
• Input Voltage: 90 - 264 Vac (Active PFC >0.95)
• Input Current: 5.0A max.
• Input Frequency: 47 - 63 Hz
• Efficiency: > 78% @ Typical load, 115Vac
• Inrush Current: 80A max. @ cold start
• Leakage Current: 600uA max. @ 240 Vac input
Dimension
DC Output:150W~270W Max
Output Rail
|
Output Voltage
|
Min. Load
|
150W O/P Max. Load
|
180W O/P Max. Load |
200W O/P Max. Load
|
220W O/P Max. Load |
250W O/P Max. Load
|
270W O/P Max. Load
|
Load Reg.
|
Ripple & Noice
|
V1
|
+12V |
0.6A
|
10A
|
12A |
14A
|
16A |
18A
|
20A
|
±5%
|
120mV
|
V2
|
+5V |
0.2A
|
11A
|
13A |
13A
|
13A |
13A
|
13A
|
±5%
|
50mV
|
V3 |
+3.3V |
0.1A
|
12A
|
14A |
14A
|
14A |
14A
|
14A
|
±5%
|
50mV
|
V5
|
-12V |
0.0A
|
0.3A
|
0.3A |
0.3A
|
0.3A |
0.3A
|
0.3A
|
±10%
|
120mV
|
V6 |
+3.3V |
0.0A
|
2A
|
2A |
2A
|
2A |
2A
|
2A
|
±5%
|
50mV
|